Secutron Products Fire Addressable/Network Fire Alarm MR-2900/2920 Series Addressable Fire Alarm Control System


MR-2900/2920 Series Addressable Fire Alarm Control System
MR-2900/2920 Series Addressable Fire Alarm Control System
View Full Image


The MR-2900 fire alarm system control unit is the heart of a sophisticated microprocessor-based fire alarm system. With the capability of networking, the MR-2900 is ideally suited for the varied needs of residential, commercial, industrial, and institutional applications. The MR-2900 provides both conventional and addressable input circuits. It has the ability to 'software' configure conventional input circuits for alarm or supervisory function, and operation with contact devices only, smoke detectors only, or both smoke detectors and contact devices with the system having the ability to differentiate between smoke detector and contact device activation. Addressable input circuits using addressable analog detectors, monitoring modules, and control modules are available using addressable input circuit modules.


Network Modules

  • MR-D1010-R2 Dual Channel Fiber Optic Modem
    RS-232 Transceiver Module to fiber,24VDC, Dual Channel (two single channel fiber optic modems in a common cabinet)
  • MR-D1010-R1 Single Channel Fiber Optic Modem
    RS-232 Transceiver Module To Fiber,24VDC,Single Channel
  • MR-2910-R2
    Network Communication Mod,Port 1 Stndrd/ Port 2 RS-232
  • MR-2910-R12
    Network Communication Mod, Port 1 RS-232/Port 2 RS-232
  • MR-2910-R1
    Network Communication Module, Port 1 RS-232 / Port 2 Std
  • MR-2910
    Network Communication Mod, Port 1 Standard/Port 2 Std
  • MR-2109-4
    RS-232 Driver for GRID or MV-2700 Interface.
  • Panel Accessories

  • MR-2920-Red
    Red Outer Front Door for MR-2920
  • MR-2920-Beige
    White Outer Front Door for MR-2920
  • MR-2900-Red
    Red Outer Front Door for MR-2900
  • MR-2900-PRT
    Parallel Printer Interface Extention Cable
  • MR-2900IDS-8BK
    Pre-configured MR-2900 Series Inner Door Assm (Class B)
  • MR-2900IDS-4AK
    Pre-configured MR-2900 Series Inner Door Assm (Class A)
  • MR-2900IDS Basic MR-2900 Series Inner Door Assembly for Custom Configuration
    MR-2900 Series Inner Door Assembly for Custom Config
  • MR-2900-Beige
    White Outer Front Door for MR-2900
  • MR20BOXR
    Extra back-box for MR-2100/2200 SER FACP ONLY
  • MR20BOXB
    Extra back-box for MR-2100/2200 SR FACP ONLY
  • Control Module

  • MR-2929
    Addressable 8 Class B / 4 Class A Loop Module
  • MR-2938
    Conventional Input Module Style D, Class inAin
  • MR-2928
    Conventional Input Module Style B, Class inBin
  • MR-2905KB
    Power Supply, Toroid (120VAC) Mounted on 2900 Back Pln
  • MR-2905KA
    Power Supply, Toroid (120VAC) Mounted on 2900 Back Pln
  • MR-2900-StyleZ
    4 Style Z (Class A) Notification Appliance (Bell) Circuits
  • MR-2900-StyleY
    8 Style Y (Class B) Notification Appliance (Bell) Circuits
  • MR-2900-DACT
    Digital Communicator Mod & Isolator Mod, MRDL UDACT DC
  • MR-2900-CITY
    City Box/ RP Transmitter Mod, MRCTYB City-tie Mod.
  • MR-2900-8MEG
    8 MB Memory for MR-2900 SERIES Database

  • Features

    • Sophisticated capabilities yet simple to operate
    • Conventional and addressable detection circuits
    • Adjustable sensitivity
    • Day/night sensitivity
    • One-person system test capability
    • Totally software driven
    • Field programmable via PC
    • Passcode protection
    • History log ~ 1400 events
    • System alarm, supervisory, and trouble relays
    • Alarm, supervisory, and trouble LEDs for each zone
    • Custom labels per zone
    • Remote alarm and trouble annunciation
    • Remote detector test capability
    • LCD supertwist 80 character (4 x 20) backlit display
    • Sprinkler supervision
    • Ground fault indication by supervised circuit
    •  Software definable conventional input circuits
    •  Conventional input circuits Style B (Class B) or Style D (Class A)
    •  Addressable input circuits Style 4 (Class B) or Style 6 (Class A)
    •  Input circuits programmable for N.O. or N.C. contacts
    •  Style Y (Class B) or Style Z (Class A) notification appliance (bell) circuits
    •  Power limited circuits
    •  DCLR network communication option
    • "Hot Key" system controls
    •  Display of real time
    •  Signal silence inhibit
    •  Signal time limit cut-out
    •  MR-2920 provides an optional panel mounted printer