Control Panels
6 Zone Fire Alarm Panel c/w LCD Display & UDACT, Red
6 Zone Fire Alarm Panel c/w LED Display & UDACT, Red
12 Zone Fire Alarm Panel c/w LCD Display & UDACT, Red
12 Zone Fire Alarm Panel c/w LED Display & UDACT, Red
6 Zone Fire Alarm Panel c/w LED Display, Red
8 Zone Fire Alarm Panel c/w LED Display, Red
Panel Modules
6 I/P Class A Converter
MR-2300 Series Output Class A Converter Mod 2 Circuits
MR-2300 Output Class A Converter Module 4 Circuits
MR-2300 Series Polarity Reversal & City Tie
MR-2300 Series 6 Relay Adder w/ 6 Relays Rated 28VDC
MR-2300 Series 12 Relay Adder w/ 12 Relays Rated 28VDC
MR-2312 Series Smart Relay Mod, 12 Configble Relays,Red
Annunciation
Remote LCD Annunciator c/w Red Semi Flush Enclosure
Remote LCD Annunciator c/w White Semi Flush Enclosure
Remote Multiplex Annunciator c/w 8 Bi Colored LEDs, Red
Remote Multiplex Annunciator c/w 16 Bi Colored LEDs, Red
Annunc.Chasis w/ 16 Bi-colrAlrm/Suprv LEDs & 16 Znd Trbl
Panel Accessories
Semi-Flush Backbox for Series1000 Annunc.,1 Mod, WH
Active End of Line Resistor (Less Plate)
MR-2306 Dead Front Front LCD Version
300 Semi Flush Trim Ring, Black, For MR-2306 Backboxes
MR-2312 Series Dead Front Front LCD Version
Universal Semi Flush Trim Ring, Black,for MR-2312 Bkboxs
MR-2312 Series Dead Front Front LED Version
Features
- Listed to UL 864, 9th edition
- Available in six, eight and twelve zone models
- Available in LED and LCD Display configurations
- LCD Display versions are equipped with a 2 line by 20 character back-lit LCD display and numerical keypad
- Integrated UDACT/Digital Communicator on select models
- Front panel and PC programmable
- LED Display versions are front panel (using CFG-300 configuration tool) and PC programmable
- Remote upload/download capabilities
- Base panel is equipped with Class 'B' (Style 'B') initiating circuits which may be configured as Class 'A' (Style 'D') using a Class "A" converter module
- Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only
- Base panel is equipped with Class 'B' (Style 'Y') indicating circuits which may be configured as Class 'A' (Style 'Z') using a Class 'A' signal converter module
- Audible signals may be configured for Steady, Temporal Code, California Code and March Time
- Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes
- Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock
- Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble
- Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test
- Subsequent Alarm, Supervisory, and Trouble operation
- RS-485 Interface for Remote LED Annunciators, LCD Annunciators and Remote Smart Relay Modules
- Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events
- 5 Amp Power Supply
- Optional modules for additional internal relay circuits and City Tie/Polarity Reversal
- Optional trim rings for semi-flush mounting
Datasheets
Manuals
- Manuals